Thin Solid Films, Vol.516, No.10, 3070-3080, 2008
Tribo-mechanical properties of thin boron coatings deposited on polished cobalt alloy surfaces for orthopedic applications
This paper presents experimental evidence that thin (< similar to 200 nm) boron coatings, deposited with a (vacuum) cathodic arc technique on pre-polished Co-Cr-Mo surfaces, could potentially extend the life of metal-on-polymer orthopedic devices using cast Co-Cr-Mo alloy for the metal component. The primary tribological test used a linear, reciprocating pin-on-disc arrangement, with pins made of ultra-high molecular weight polyethylene. The disks were cast Co-Cr-Mo samples that were metallographically polished and then coated with boron at a substrate bias of 500 V and at about 100 degrees C. The wear tests were carried out in a saline solution to simulate the biological environment. The improvements were manifested by the absence of a detectable wear track scar on the coated metal component, while significant polymer transfer film was detected on the uncoated (control) samples tested under the same conditions. The polymer transfer track was characterized with both profilometry and Rutherford backscattering spectroscopy. Mechanical characterization of the thin films included nano-indentation, as well as additional pin-on-disk tests with a steel ball to demonstrate adhesion, using ultra-high frequency acoustic microscopy to probe for any void occurrence at the coating-substrate interface. (c) 2007 Elsevier B.V. All rights reserved.
Keywords:boron;amorphous materials;coatings;biomaterials;deposition process;Rutherford backscattering spectroscopy;tribology;cobalt alloy