Energy Conversion and Management, Vol.50, No.10, 2638-2649, 2009
Experimental investigation of heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of Left-Right twisted tapes
Experimental investigation of heat transfer and friction factor characteristics of thermosyphon solar water heater with full length Left-Right twist, twist fitted with rod and spacer at the trailing edge for lengths of 100, 200 and 300 mm for twist ratio 3 and 5 has been studied. The experimental data for plain tube collector has been compared with fundamental equation within a discrepancy of +/-7.41% and +/-14.97% for Nusselt number and friction factor, respectively. Result shows that the Nusselt number decreases by 11% and 19% for twist fitted with rod and twist with spacer, respectively, when compared with full length twist. Friction factor also decreases by 18% and 29% for twist fitted with rod and spacer, as compared with full length twist. The heat enhancement in twist fitted with rod at the respectively, trailing edge is maximum when compared with twist fitted with spacer because the swirl flow is maintained throughout the length of rod. (C) 2009 Elsevier Ltd. All rights reserved.