International Journal of Energy Research, Vol.33, No.12, 1040-1047, 2009
Transcritical CO2 refrigerator and sub-critical R134a refrigerator: A comparison of the experimental results
This paper describes experiments comparing a commercial available R134a refrigeration plant subjected to a cold store and a prototype R744 (carbon dioxide) system working as a classical 'split-systems' to cool air in residential applications in a transcritical cycle. Both plants are able to develope a refrigeration power equal to 3000 W. The R744 system utilizes aluminium heat exchangers, a semi-hermetic compressor, a back-pressure valve and a thermostatic expansion valve. The R134a refrigeration plant operates using a semi-hermetic reciprocating compressor, an air condenser followed by a liquid receiver, a manifold with two expansion valves, a thermostatic one and a manual one mounted in parallel, and an air cooling evaporator inside the cold store. System performances are compared for two evaporation temperatures varying the temperature of the external air running over the gas-cooler and over the condenser. The refrigeration load in the cold store is simulated by means of some electrical resistances, whereas the air evaporator of the R744 plant is placed in a very large ambient. The results of the comparison are discussed in terms of temperature of the refrigerants at the compressor discharge line, of refrigerants mass flow rate and of coefficient of performance (COP). The performances measured in terms of COPs show a decrease with respect to the R134a plant working at the same external and internal conditions. Further improvements regarding the components of the cycle are necessary to use in a large-scale 'split-systems' working with the carbon dioxide. Copyright (C) 2009 John Wiley & Sons, Ltd.