International Journal of Heat and Mass Transfer, Vol.51, No.19-20, 4926-4939, 2008
Two-phase pressure drops in a helically coiled steam generator
An experimental investigation regarding two-phase diabatic pressure drops inside a helically coiled heat exchanger have been carried out at SIET thermo-hydraulics labs in Piacenza (Italy). The experimental campaign is part of a wide program of study of the IRIS innovative reactor steam generator. The test section consists of all AISI 316 stainless steel tube, 32 in length, 12.53 mm inner diameter, curved in helical shape with a bend radius of 0.5 m and a helix pitch of 0.8 m, resulting in a total height of the steam generator tube of 8 m. The explored operating conditions for two-phase flow experiences range from 192 to 824 kg/m(2) s for the mass flux, from 0 to 1 for the quality, from 1.1 to 6.3 MPa for the pressure, from 50 to 200 kW/m(2) for the heat fluxes. A frictional two-phase pressure drops correlation, based oil an energy balance of the two-phase mixture and including the 940 experimental points, is proposed. Comparison with existing correlations shows the difficulty in predicting two-phase pressure drops in helical coil steam generators. (C) 2008 Elsevier Ltd. All rights reserved.