화학공학소재연구정보센터
Journal of Hazardous Materials, Vol.163, No.2-3, 511-516, 2009
Use of modified sorbent for the separation and preconcentration of chromium species from industrial waste water
A simple and sensitive method based on solid phase extraction (SPE) on acetyl acetone modified XAD-16 has been established for separation of Cr (III) and Cr (VI) from and industrial water samples. Two forms of chromium showed different exchange capacities at different pH values, viz. Cr (III) selectively retained at pH 5-7 whereas Cr (VI) retained at pH 1. Hence complete separation of the two forms of chromium is possible. Retained species were eluted with 5 mL of 2 mol L-1 HNO3 and 2 mol L-1 NaOH. The detection limit of 0.02 and 0.014 mu g mL(-1) was achieved for Cr (III) and Cr (VI), respectively, with an enrichment factor of 100 and 140. Various kinetic and thermodynamic parameters were also determined. The metal ion concentration was measured by atomic Absorption Spectroscopy. The possible retention mechanism is also discussed. The method was successfully applied for the speciation of chromium in industrial water samples. (c) 2008 Elsevier B.V. All rights reserved.