화학공학소재연구정보센터
Indian Journal of Chemical Technology, Vol.2, No.6, 307-310, 1995
CONTINUOUS TAPERED FLOCCULATION IN CONICAL AND CYLINDRICAL TANKS
The progressive reduction of velocity gradient to keep the flocculation rate as high as possible without breakage of flocs is called 'tapered flocculation'. In the present work, an attempt has been made to compare the performance of continuous tapered flocculation in conical and cylindrical tanks. The efficiency of conical flocculator was found to be higher than that of cylindrical flocculator, especially at higher flow rates.