화학공학소재연구정보센터
Powder Technology, Vol.193, No.1, 93-100, 2009
Measurement of particle concentration in powder coating process using capacitance computed tomography and wavelet analysis
Capacitance computed tomography techniques were used to visualize particles movement in the draft tube of a spouted fluidized bed for the coating process of drug production. A total of 512 frames images of the particle concentration distribution were obtained at 10-millisecond intervals over a coating time of 5 min using a capacitance computed tomography system. The three-dimensional capacitance CT images (time and two-dimensional space images) were decomposed to wavelet time and space levels to extract the dominant particle distribution feature using three-dimensional discrete wavelet multiresolution at different coating times. As a result, the time and space dominant particle distribution with a specific frequency level can be visualized. (C) 2009 Elsevier B.V. All rights reserved.