Chemistry and Technology of Fuels and Oils, Vol.45, No.6, 399-401, 2009
STRIPPING OF HYDROGEN SULFIDE FROM VISBREAKING RESID
Technical and production solutions ensuring a commercial boiler fuel with a hydrogen sulfide content of no more than 2 ppm are developed as a result of the basic design of a unit for stripping hydrogen sulfide from visbreaking resid. The potential exists for a further increase in the output of the visbreaking plant to 2 million tons/year, where the actual output achieved is 1.4 million tons/year.