화학공학소재연구정보센터
Industrial & Engineering Chemistry Research, Vol.37, No.7, 2662-2667, 1998
Hydrodesulfurization catalyst evaluation in an upflow three-phase microreactor
The application of a fully automated upflow three-phase microreactor to evaluation of a hydrodesulfurization catalyst is illustrated. Reliable kinetic parameters are obtained, showing that solvent vaporization is carefully accounted for. Despite the small dimensions of the reactor (120 mm long, 6 mm i),it is possible to define experimental conditions where plug flow prevails and gas-liquid mass transfer is instantaneous.