Journal of Crystal Growth, Vol.312, No.19, 2677-2682, 2010
In-situ observations of dissolution process of GaSb into InSb melt by X-ray penetration method
Dissolution process of GaSb into InSb melt was observed by an X-ray penetration method. The intensity of X-rays penetrated through the rectangular shaped GaSb (seed)/InSb/GaSb (feed) sandwich sample was recorded by the CdTe line sensor detector. The penetrated X-ray intensities and images of the sample were obtained as a function of time and temperature. The gallium (Ga) composition profile of the sample was calculated as a function of time by making the calibration line with the penetrated X-ray intensities of GaSb and InSb standard samples. The calculated Ga composition profile of the grown sample agreed well with the data measured by energy dispersive X-ray spectroscopy analysis. The result suggested that lower GaSb seed dissolved faster than upper GaSb feed despite of the low temperature at the lower GaSb seed. It clearly indicates that the solutal transport induced by gravity strongly affects the dissolution process. (C) 2010 Elsevier B.V. All rights reserved.