Journal of Power Sources, Vol.195, No.19, 6732-6739, 2010
Optimum start-up strategies for direct internal reforming molten carbonate fuel cell systems
The study of start-up performance for a direct internal reforming molten carbonate fuel cell (DIR-MCFC) system is presented. Since a kW-class stack is assembled with an additional preheating design, the improvement of start-up behavior is conducted to find the proper operating strategy. For a cold start-up fuel cell system, both start-up delay and inverse response are strictly detected. When the optimum operating strategy is determined by solving the steady-state optimization algorithm subject to stack temperature constraint, the rapid system start-up as well as the maximum power output can be achieved simultaneously. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.