Energy Conversion and Management, Vol.52, No.2, 1426-1438, 2011
Jatropha oil and biogas in a dual fuel CI engine for rural electrification
This work presents the first dual fuel measurements with pure jatropha oil and biogas, using a 12 kW diesel engine generator. Reference tests are done with pure jatropha oil and with diesel to characterize the engine's thermal efficiency eta(t), volumetric efficiency eta(v) and air-excess ratio lambda versus output power. An extensive parameter study is done to predict/explain the effect of dual fuel operation on eta(v), and lambda. Dual fuel experiments, adding different qualities (CH4/CO2 ratios) of synthetic biogas to the intake air, show that thermal efficiency is hardly affected for higher loads. For lower loads, biogas addition results in a decrease up to 10% in thermal efficiency, independent of biogas quality. Both eta(v) and lambda decrease with addition of biogas, in quantitative agreement with predictions. The engine runs well up to a certain heat release fraction of methane; at higher fractions irregularities are observed, probably attributable to light end-gas knock. (C) 2010 Elsevier Ltd. All rights reserved.