Journal of Bioscience and Bioengineering, Vol.113, No.6, 788-791, 2012
High-throughput method for a kinetics analysis of the high-pressure inactivation of microorganisms using microplates
Using microplates as pressure and cultivation vessels, a high-throughput method was developed for analyzing the high-pressure inactivation kinetics of microorganisms. The loss of viability from a high-pressure treatment, measured based on the growth delay during microplate cultivation, showed reproducibility with the conventional agar plate method and was applicable for the kinetics analysis. (C) 2012, The Society for Biotechnology, Japan. All rights reserved.
Keywords:Microplate;High-throughput;High-pressure;Microbial inactivation;Escherichia coli;Saccharomyces cerevisiae