화학공학소재연구정보센터
International Polymer Processing, Vol.13, No.1, 71-77, 1998
Temperature measuring in plastics processing with infrared radiation thermometers - The influence of the absorption coefficient
In many areas of plastics processing the temperature is a decisive process control parameter. infrared sensors that detect the heat radiation from molten plastic have a response time in the range of milliseconds. Thus in many processes they offer the only possibility to measure time dependent temperatures with high accuracy