학회 |
한국화학공학회 |
학술대회 |
2010년 가을 (10/21 ~ 10/22, 대전컨벤션센터) |
권호 |
16권 2호, p.1408 |
발표분야 |
공정시스템 |
제목 |
Influences of system configuration and operationg condition on molten carbonate fuel cell efficiency |
초록 |
MCFC system which is operated about 650℃ is composed of the stack and the BOP. In this study, 1.2MW MCFC system at steady state is simulated by the Aspen Plus. The configuration of MCFC system and essential operating conditions are changed and then the efficiency of each case is analyzed. To analyze the efficiency of the system, both the Energy analysis and the Exergy analysis are performed. Exergy is the amount of energy "free of entropy" and is the maximum work output attainable in natural environment. From the exergy analysis, the real energy loss and efficiency loss by irreversibility which can't revealed by energy analysis is calculated. In this study, meaningful efficiency of MCFC is calculated through the exergy analysis and the method of optimization isconsidered. As the results of the analysis , according as the system configuration changes, efficiency is varied less than 0.5%. However according as the systemoperating conditions are changed, efiiciency is increased from 1.5% to 11%.Financial supported from the Ministry of Knowledge Economy(MKE) in 2008 and this research was supported by the Korea Institute of Energy Technology Evaluation and Planning(KETEP)(2008-N-FC12-J-04-2100). |
저자 |
곽하연1, 양대륙1, 경지현1, 이태원2, 문길호2, 이기풍2, 류아림2
|
소속 |
1고려대, 2두산중공업 기술(연) |
키워드 |
MCFC; Exergy; Energy
|
E-Mail |
|
원문파일 |
초록 보기 |