화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2005년 봄 (04/22 ~ 04/23, 여수대학교)
권호 11권 1호, p.1093
발표분야 화학공정안전
제목 Flash Points and Fire Points of Flammable Liquid Mixture Using Tag Open-Cup Apparatus(ASTM D1310)
초록 The flash point are used to classify combustible liquids according to their relative flammability. The flash and fire points for the n-propanol+n-decane mixture were measured by Tag open-cup apparatus. The experimental results exhibited the flash point, i. e., less than those of pure component in the flash point versus composition curve. The experimental value of the minimum flash point is 27℃ at a mole fraction of n-propanol of 0.71, and the flash points of n-propanol and n-decane were 28℃ and 54℃, respectively. The experimental data were compared with the values calculated by the prediction model based on an ideal solution assumption and the flash point prediction models based on the van Laar, respectively. The predictive curve based upon an ideal solution deviated form the experimental data for this system. The experimental results are in good agreement with the predictive curves, which use the van Laar. The average absolute deviations by using van Laar equation is 0.83℃.
저자 하동명1, 한종근1, 김일권1, 유희환1, 김평호1, 박영선1, 장수영1, 이민권1, 이성진1, 송영호2, 최용찬3
소속 1세명대, 2충북대, 3(주)리셋피앤디
키워드 Tag open-cup apparatus(ASTM D 1310); flash point; flammanble liquid mixture
E-Mail
원문파일 초록 보기