IEEE Transactions on Automatic Control, Vol.60, No.3, 775-780, 2015
Designing Controllers With Reduced Order Internal Models
In this technical note we study robust output tracking for autonomous linear systems. We introduce a new approach to designing robust controllers using a recent observation that a full internal model is not always necessary for robustness. Especially this may be the case if the control law is only required to be robust with respect to a specific predetermined class of uncertainties in the parameters of the plant. The results are illustrated with an example on robust output tracking for coupled harmonic oscillators.